Variable Speed Drives



Manufacturer Model Designation
output range
minimum maximum
motor voltage frequency rectifier_type drive type step
semiconductors
rectifier inverter
motor_type cooling
ABB  ACS 1000  315  5000  4  82  12, 24  VSI    Diodes  IGCTs  IM  A, W
ABB  ACS 5000  1700  22000  7  200  36  VSI    Diodes  IGCTs  IM, SM  A, W
ABB  ACS 6000  3000  27000  3  75  12, 24/AFE  VSI    Diode/IGCT  IGCTs  IM, SM  W
ABB  MEGADRIVE-LCI  2000  72000  10  120  6, 12, 24  LCI  6, 12  Thyristors  Thyristors  SM  A, W
Converteam SAS  MV7000  4000  32000  7  300  6, 12, 24, AFE  VSI  6  Diode-PPI  PPI  IM-SM  W
Converteam SAS  SD7000  2500  1000000  10  120  6, 12, 24  LCI  6, 12  Thyristor  Thyristor  SM  W
Converteam SAS  MV3000  22  6000  1  250  6,12,24  VSI  6  diode-thyr  LV IGBT  IM  A & W
Converteam SAS  MV3000  22  6000  1  250  AFE  VSI  6  LV IGBT  LV IGBT  IM  A & W
Siemens Energy  SINAMICS  0  1200  690    6, 12  VSI    Diodes  LV IGBT  IM  A
Siemens Energy  Simovert MV  500  8000  7  125  12, 24  VSI    Diodes  HV IGBT  IM  A & W
Siemens Energy  ML2  5000  28000  3  80  6 (AFE)  VSI    HV IGCT  HV IGCT  SM  W
Siemens Energy  Simovert S  2500  70000  13  120  6, 12  LCI  6, 12  Thyristor  Thyristor  SM  A & W
Siemens Energy  Robicon Perfect Harmony  350  35000  13  330  18, 36  VSI    Diodes  LV IGBT  IM; SM  A & W
Siemens Energy  SINAMICS GM150 (succ. of MV)  500  8000  7  250  12, 24  VSI    Diodes  HV IGBT  IM, SM  A & W
Siemens Energy  SINAMICS GM150  8000  25000  3  250  12, 24  VSI    Diodes  HV IGCT  IM, SM  W
Siemens Energy  SINAMICS SM150 (succ. of ML2)  5000  28000  3  250  6 (AFE)  VSI    HV IGCT  HV IGCT  IM, SM  W